Project Detail
Project: Blue Lake Unit 01
Equipments: Rig and/or Derrick: Drilling Pipe Wrangler
Date: February 2014
Vendor Location: Fabricator of Derrick Equipments in Nuevo Leon, Mexico.
Visual Inspection on Welds per Customer Document 000378 Rev 07/ (Inspection and Testing Requirements) Item 10 and Vendor Drawing 15040045 Rev B.
Item Inspected: Blasted Rig Equipment.
Findings: Several fillet welds observed not properly tied into adjacent welds at edges of internal gussets.
Re-Inspection: Repaired by Vendor before final Blasting and Painting. See photo on weld defects as detected.
Visual Inspection on Welds per Customer Document 000378 Rev 07 (Inspection and Testing Requirements) Item 10 and Vendor Drawing-1040054 Rev A.
Item Inspected: Blasted Derrick Equipment.
Findings: Several locations at edges of beams observed with damagings by not proper handling during fabrication process.
Re-Inspection: Repairs completed by Vendor before final Blasting and Painting. See photo on described issue.
Benefits to Our Customer: By using Fraza Inspection Team, Customer saved a lot of of time and money preventing excessive expenses per back charges for Re-works at field site per unacceptable issues on Welding, if Not Corrected/Repaired in timely manner at Vendor Shop.
© 2019 Fraza Inspection Company - All Rights Reserved
Project #1
Project Detail
Project: Blue Lake Unit 01
Equipments: Rig and/or Derrick: Drilling Pipe Wrangler
Date: February 2014
Vendor Location: Fabricator of Derrick Equipments in Nuevo Leon, Mexico.
Item #1
Visual Inspection on Welds per Customer Document 000378 Rev 07/ (Inspection and Testing Requirements) Item 10 and Vendor Drawing 15040045 Rev B.
Item Inspected: Blasted Rig Equipment.
Findings: Several fillet welds observed not properly tied into adjacent welds at edges of internal gussets.
Re-Inspection: Repaired by Vendor before final Blasting and Painting. See photo on weld defects as detected.
Item #2
Visual Inspection on Welds per Customer Document 000378 Rev 07 (Inspection and Testing Requirements) Item 10 and Vendor Drawing-1040054 Rev A.
Item Inspected: Blasted Derrick Equipment.
Findings: Several locations at edges of beams observed with damagings by not proper handling during fabrication process.
Re-Inspection: Repairs completed by Vendor before final Blasting and Painting. See photo on described issue.
Benefits to Our Customer: By using Fraza Inspection Team, Customer saved a lot of of time and money preventing excessive expenses per back charges for Re-works at field site per unacceptable issues on Welding, if Not Corrected/Repaired in timely manner at Vendor Shop.