Project Detail
Project: Beauty Mountain Unit 03
Equipment: Induction Motor and Main Conduit Box
Date: August 2018 to October 2018
Vendor Location: Fabricator of Induction Motors in Nuevo Leon, Mexico.
Final Visual Inspection on Painting per ITP-BM-12502-03 Rev 1 Item 10.1 and Customer Paint Specification BM-12502-PS-02 Rev 1.
Item Inspected: Completed Induction Motor.
Findings: Several locations with not full coating coverage, areas observed painted over foreign material, as well other ones found with painting applied over surfaces extremely contaminated with oil.
Re-Inspection: Vendor has completed on all needed repairs as confirmed by Visual Inspection. See Photos on Described Issues as originally found.
Final Visual Inspection per ITP-BM-12502-03 Rev 1 Item 4.1 and Drawing 12502-BM-01 Rev 2.
Item Inspected: Completed Induction Motor.
Findings: Spatter in Several Locations and welds showing porosity and not properly seal welded, Not Acceptable to referenced drawing.
Re-Inspection: Vendor has completed on all needed repairs as confirmed by Visual Inspection. See Photos on Described Issues as originally found.
Benefits to Our Customer: By using Fraza Inspection Team, Customer saved a lot of of time and money preventing excessive expenses per back charges for Re-works at field site per unacceptable issues on Welding and Painting, if Not Corrected/Repaired in timely manner at Vendor Shop
© 2019 Fraza Inspection Company - All Rights Reserved
Project #1
Project Detail
Project: Beauty Mountain Unit 03
Equipment: Induction Motor and Main Conduit Box
Date: August 2018 to October 2018
Vendor Location: Fabricator of Induction Motors in Nuevo Leon, Mexico.
Item #1
Final Visual Inspection on Painting per ITP-BM-12502-03 Rev 1 Item 10.1 and Customer Paint Specification BM-12502-PS-02 Rev 1.
Item Inspected: Completed Induction Motor.
Findings: Several locations with not full coating coverage, areas observed painted over foreign material, as well other ones found with painting applied over surfaces extremely contaminated with oil.
Re-Inspection: Vendor has completed on all needed repairs as confirmed by Visual Inspection. See Photos on Described Issues as originally found.
Item #2
Final Visual Inspection per ITP-BM-12502-03 Rev 1 Item 4.1 and Drawing 12502-BM-01 Rev 2.
Item Inspected: Completed Induction Motor.
Findings: Spatter in Several Locations and welds showing porosity and not properly seal welded, Not Acceptable to referenced drawing.
Re-Inspection: Vendor has completed on all needed repairs as confirmed by Visual Inspection. See Photos on Described Issues as originally found.
Benefits to Our Customer: By using Fraza Inspection Team, Customer saved a lot of of time and money preventing excessive expenses per back charges for Re-works at field site per unacceptable issues on Welding and Painting, if Not Corrected/Repaired in timely manner at Vendor Shop